3 communication, 1 controller with can bus, 2 controller with profibus – Lenze E931Ex User Manual

Page 17: Communication, Controller with can bus, Controller with profibus, Technical data

Advertising
background image

Technical data

Communication

Controller with CAN bus

3

l

17

GHB 13.0001−EN EN 3.0

3.3

Communication

3.3.1

Controller with CAN bus

Area

Values

Communication profile

DS 301, DSP 402

Communication medium

RS232

Network topology

Without repeater: line / with repeaters: line or tree

CAN node

Slave

Baud rate (in kbps)

10, 20, 50, 100, 125, 250, 500

Maximum cable length per bus
segment

1200 m (dependent on baud rate and cable type used)

Bus connection

RJ45

3.3.2

Controller with PROFIBUS

Area

Values

Communication profile
(DIN 19245 part 1 and part 3)

PROFIBUS−DP−V0

Communication medium

RS485

Drive profile

PROFIdrive

Network topology

Without repeater: line / with repeaters: line or tree

PROFIBUS−DP station

Slave

Baud rate [kbps]

9.6 ... 12000

Maximum cable length per bus
segment

1200 m (dependent on the baud rate and cable type used)

Bus connection X4.1, X4.2

9−pin Sub−D socket