Error message

7

l

41

GHB 13.0001−EN EN 3.0

Remedy

Cause

Reaction

Red LED is
blinking

Remedy

Cause

O

W

h

A

Red LED is
blinking

6x

þ

Overcurrent / short
circuit

Check motor cable and motor phases with
regard to a short circuit of the phases or
the drive

5x

þ

System error

Switch off and then reconnect control
voltage. If the error re−occurs, send in the
drive.

4x

þ

¨

Overtemperature drive
controller

l

Check correct mounting in the control
cabinet:
– Heatsink has to fit extensively to the

housing of the control cabinet.

– Are further heat sources mounted

near the drive controller, bringing
about an increased ambient
temperature of the inverter?

l

Check whether the ventilation slots of
the drive controller are soiled or
blocked. If required, clean.

l

Optimise controller settings (bad
settings result in an unnecessary
heating). (

, 931E Software Manual)

l

Check resolver adjustment. (

, 931E

Software Manual)

l

Reduce load torque of the motor.

3x

þ

¨

¨

¨ Overtemperature motor

l

Check whether the motor cooling via
the motor housing is prevented by
deposits, etc.(if required, cleaning of the
motor).

l

Are there further heat sources near the
motor, bringing about an additional
increase in the predominant ambient
temperature, and thus contributing to a
diminution of the dissipation of lost
heat?

l

Check controller settings, bad settings
result in an unnecessary heating.
(

, 931E Software Manual)

l

Reduce load torque of the motor.

l

Check setting of the thermal sensor.

l

Check resolver cable or encoder cable
with regard to open circuit.

l

Check resolver adjustment. (

, 931E

Software Manual)

2x

þ

¨

¨

¨ Undervoltage in the DC

bus

l

Check DC−bus voltage, if required,
adjust undervoltage trigger level.
(

, 931E Software Manual)

1x

¨

¨

þ

¨ MMC not connected

l

Check setting of multimedia card
(MMC).

l

Connect MMC.

l

Change setting of the error tracking
system by means of the
parameterisation software.