5 control terminals, Control terminals, Electrical installation – Lenze E931Ex User Manual

Page 26

Advertising
background image

Electrical installation

Control terminals

5

l

26

GHB 13.0001−EN EN 3.0

5.5

Control terminals

The digital and analog inputs and outputs are placed in the plug X5. The digital and analog
inputs and outputs have the same reference potential.

X5 inputs and outputs

Pin No. Signal

Function

Specification

Lenze

Alternatively
adjustable via
SDC

1

+AIN0 (DIN0) Analog input 0

differential
(speed setpoint, current
setpoint)

DIN0

Input voltage

−10 V ... +10 V

Overvoltage protection

−30 V ... +30 V

2

−AIN0 (DIN1)

DIN1

Input impedance

> 20 k

W

Resolution

12 Bit

3

+AIN1 (DIN2) Analog input 1

differential

DIN2

Offset error

< ± 50 mV

Gain error

< 5 %

4

−AIN1 (DIN3)

DIN3

Limiting frequency

~ 1 kHz

5

+AMON0

Analog monitors
output of internal quantities (current, speed,
etc.)

Output signal

0 V ... 10 V,
max. 2 mA

6

+AMON1

7

GND

Reference potential for pin 1 ... 6, pin 8 ... 16

8

DIN4

Digital input 4

Rated voltage

+24V DC

9

DIN5

Digital input 5

Voltage range

0 ... +30 V DC

10

DIN6

Digital input 6

HIGH signal

> +8 V DC

11

DIN7

Digital input 7

LOW signal

< +4 V DC

12

DIN8

Digital input 8

Input impedance

> 4.7 k

W

13

DIN9

Digital input 9
(controller enable / delete error)

Switching delay
(LOW−HIGH transmission)

< 1 ms

14

DOUT0

Digital output 0
(ready for operation)

Output voltage

0 V / 24 V

LOW signal

0 ... 4 V DC

HIGH signal

18 V ... 30 V

15

DOUT1

Digital output 1

Output current

max. 10 mA

Load impedance

> 2.2 k

W

16

DOUT2

Digital output 2

Switching delay
(LOW−HIGH transmission)

< 1 ms

Terminal data

Max. conductor cross−section

Tightening torque

Screw drive

Cable

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

7 mm

2.5

12

0.5 ... 0.6

4.4 ... 5.3

Slot 0.6 x 3.5

With wire end
ferrule

Advertising