Commissioning
Initial switch−on
l
35
GHB 13.0001−EN EN 3.0
9. Parameterise the analog terminals in the "Parameters
W I/Os... W Analog inputs"
menu:
– Here you assign the setpoint quantity to the voltage level.
– By means of the offset, you can adjust the potentiometer.
– By means of the slide control "safe null", you can define a range where the motor
is safely stopped.