Connection of PROFIBUS

Assignment of Sub−D socket

The controller is connected to the PROFIBUS via the 9−pin Sub−D socket X4.1/X4.2.

View

Pin

Designation

Explanation

1

6

5

9

1

2

3

RxD/TxD−P

Data line B (received/transmitted data plus)

4

RTS

Request to send
(received/transmitted data, no differential signal)

5

M5V2

Data reference potential (ground to 5V)

6

P5V2

5 V DC / 30 mA (bus termination)

7

8

RxD/TxD−N

Data line A (received/transmitted data minus)

9

5.7.4

Connection of RS232 serial interface to X1

The serial interface is designed as a 9−pole Sub−D−plug. The signal levels comply with the
RS232 specification.

X1 RS232

Pin No. Designation

Value

1

n. c.

Not assigned

2

R x D

0 V / 10 V

3

T x D

0 V / 10 V

4

n. c.

Not assigned

5

GND

6

n. c.

Not assigned

7

8

9