Key for the overview

0 View from the front
Pos.

Description

X1

RS232

X5

Digital inputs and outputs / analog inputs and outputs

X6

Slot for multimedia memory card

1 931EC ˘ View from above
Pos.

Description

X2

Voltage supply

X4.1
X4.2

CAN interfaces

X10

Digital frequency interface

2 931EP ˘ View from above
Pos.

Description

X2

Voltage supply

X4.1/X4.2

PROFIBUS interface

X10

Digital frequency interface

3 View from below
Pos.

Description

X3

Motor connection

X7

Resolver input

X8

SinCos encoder input

LED

Colour

State

Note

State

Green

on

The control is correctly supplied by a 24 V control voltage, the drive is ready for operation.

blinking

Data is written on or read from the memory card.

off

No voltage

Power

Yellow

on

The power section is enabled, the motor is supplied with voltage. The drive works with the set
control.

off

The drive does not work, the output stage is inactive.

Error

Red

off

No fault

blinking

Internal drive error

1)

After the cause of the error has been eliminated, you have to acknowledge the error message:

l

Either by using the parameterisation software, or via an edge at DIN9 (controller enable).

l

If no error is active anymore, the LED goes out.

Green
Yellow
Red

on

l

The drive is in the initialisation phase after the control voltage has been switched on.

l

A new firmware is being installed.

1)

Detailed description of the blink codes:

^ 40

)

Note!

The light−emitting diode "Error" constantly blinks if a fault is active:

ƒ

It only displays one fault at a time.

ƒ

If several faults are active at the same time, the fault that occured first is displayed.