Electrical installation

Important notes

5

l

20

GHB 13.0001−EN EN 3.0

5

Electrical installation

5.1

Important notes

(

Stop!

The drive controller contains electrostatically sensitive components.
The personnel must be free of electrostatic charge when carrying out assembly
and service operations.

{

Danger!

ƒ

The connection of all pluggable terminals has to be effected in a
deenergised state.

ƒ

Connecting and disconnecting the voltage supply (X2) due to the charging
processes of the DC bus capacitor may cause traces of burning on the
plug−in connection, and may result in a destruction of the internal electronic
circuit.

ƒ

A false polarity of the DC supply can bring about the destruction of the
drive. Before switching the drive on, ensure that the polarity of the
DC supply is correct.

)

Note!

The following requirements have to be met with regard to the trouble−free
operation:

ƒ

An installation according to EMC.

ƒ

The shield of the motor cable has to be applied to PE potential on a
preferably large surface in order to prevent negative effects.

ƒ

The resolver cable, encoder cable, and the motor cable may have a
maximum length of 15 m!

ƒ

The feeding power supply units have to be sufficiently dimensioned. The
power supply units have to be protected against overcurrent by means of
appropriate input fuses.