Device description – Lenze ETCxxxxx User Manual

Page 33

Advertising
background image

Device description

Module

Power supply unit

3

3.4

3.4.1

l

33

EDSTCXX EN 2.0

9 ... 12

LED 5 V, LED 24 V
F1

S1, S2

ME

1 ... 4

ETC007

Terminal

Designation

Meaning

Comment

1

+24 V

Voltage supply

2

0 V

Reference potential

9

C_H

CAN High

To extend the ME bus
to external modules

10

C_L

CAN Low

11

C_Gd

CAN signal earth

12, 3, 4

CAN shield potential, shielding

Terminals bridged
internally

S1

Switch for CAN bus termination

On = termination with
120 Ohm between C_H
and C_L

F1

Fuse

Plug−in Microfuse 5 A,
125 V (manufacturer
Wickmann No.
303−1500−042); pull to
replace

LED 5 V

Live LED 5 V and 24 V

Illuminate if voltage is
adequate

LED 24 V

ME

ME bus

Elements