2 technical data, 1 general data and operating conditions, Technical data – Lenze ETCxxxxx User Manual

Page 8: General data and operating conditions, 2technical data

Advertising
background image

Technical data

General data and operating conditions

2

2.1

l

8

EDSTCXX EN 2.0

2

Technical data

2.1

General data and operating conditions

Type

ETCHx

ETCPx

Labelling and approval

CE (compliance with the EMC Directive)

Climatic conditions

Storage

1 K3 per IEC/EN 60721−3−2

Temperature

−20 °C ... +60 °C;

D

max

= 20 K/h

Transport

2 K3 per IEC/EN 60721−3−2

Temperature

−20 °C ... +60 °C;

D

max

= 20 K/h

Operation

1)

3 K3 per IEC/EN 60721−3−2

Temperature

−0 °C ... +50 °C;

D

max

= 10 K/h

above 1000 m site altitude permissible temperature reduced by 1 K/300 m

Atmospheric pressure

860 hPa to 1060 hPa

Rel. humidity

8 % ... 80 % (non condensing)

Vibration resistance

Shock (10 ms)

max. 5 G

Vibration (5 ... 100 Hz)

max. 0.5 G

Noise immunity

EN50082−1 = severity 3

Noise emission

EN50082−2 = limit value B

Packaging

Dustproof packaging

Protection category

IP20

IP00

Installation position

vertical

Installation clearances

top and bottom 80 mm

1)

At maximum load, vertical installation and sufficient convection

Advertising