Troubleshooting and fault elimination

Battery replacement

6

6.4

l

66

EDSTCXX EN 2.0

The battery used is from the type CR 2430.

1. Unlock the locks

0 on both sides using a suitable tool (e.g. screwdriver)

by applying pressure.

ECKELMANN

Industrieautomation

0

0

ETC044

2. Remove upper housing

1 and pull the circuit boards 2 from the

housing base.

2

1

ETC045

ETCHx