4 identification, Identification, Product description – Lenze EMZ9374IB User Manual
Page 49
Product description
Identification
l
49
EDBMZ9374X DE/EN/FR 4.2
3.4
Identification
9374_011
33.9374IB
xx
xx
33.9374IB
0B
01
33.9374IB
0C
02
33.9374IB
0C
05
33.9374IB
1A
10
Type
Hardware version
Software version
3.5
Notes on the function and compatibility of the versions
9374
9374
9374
9374
CAN
CAN
CAN
CAN
CAN
9374-Master
9374-Slave1
9374-Slave2
9374-Slave3
Slave
Master
9374_012
Version
Function
Compatibility
33.9374IB.0B.01
When inputs and outputs are operated, the
outputs may be live even if the power supply is
switched off. Remedy:
l
Operation of inputs exclusively
l
Operation of outputs exclusively
l
For special wiring when inputs and output
are operated see
No operation as 9374
slave possible. Faulty
triggering of the terminal
extension.
33.9374IB.0C.02
No restriction
33.9374IB.0C.05
No restriction
33.9374IB.1A.10
Operation of inputs and outputs without any
special measures.
l
For wiring see
^
No restriction