Electrical installation

Wiring for the operation of inputs and outputs

6

l

52

EDBMZ9374X DE/EN/FR 4.2

6

Electrical installation

6.1

Wiring for the operation of inputs and outputs

ƒ

The wiring is required for the versions:

33.9374IB.0B.01, 33.9374IB.0C.02, 33.9374IB.0C.05

GND

I/O1 I/O2 I/O3 I/O4 I/O5 I/O6

GND

I/O7

LO

I/O8

HI

mC

- +

GND

24V

OUT

24V

1

2

3

4

5

0 ~

PE

9374_013

0

Power supply with +24 VDC output voltage

l

When dimensioning the power supply take into account the currents at the
outputs (max. 1 A per output).

1

Emergency switch

l

It must be ensured that the outputs do not carry any voltage and the inputs do
not receive a HIGH signal when the switch is actuated.

2

Digital inputs with normally−open contact

3

Digital outputs with consumer

4

System bus (CAN) (

^

56)

5

PE connection (6.3 mm AMP connector)

l

Connect the PE connection with the conductive rear panel of the control
cabinet. This ensures a troublefree operation of the terminal extension.

{

Danger!

Install an additional mains isolation if

ƒ

the terminal extension is connected to a host,

ƒ

a safe mains isolation (double insulating distance) according to
EN 50178 is necessary.