Commissioning

Configuration with internal DIP switches

Settings in the operating mode (normal operation)

7

l

61

EDBMZ9374X DE/EN/FR 4.2

Addressing of the terminal extension
Kommunikation zwischen Klemmenerweiterung und Antriebsregler

CAN-IN

769

CAN-OUT

770

CAN-OUT

767 + 2 = 769

CAN-IN

768 + 2 = 770

9374

C0350 = 1

A

1

A

2

PDO-TX

PDO-RX

9374_006

A

1

Controller with CAN bus node address 1 (C0350 = 1)

A

2

Terminal extension with CAN bus node address 2

Input/Output information is exchanged via the process data channel (PDO =
Process Data Object). Two process data messages (PDO−TX, PDO−RX) transmit
information. For the transmission, every message needs a CAN bus identifier
which consists of the addition of basis identifier and CAN bus node address of the
terminal extension (CAN bus identifier = basis identifier + CAN bus node
address).

ƒ

PDO−TX: The terminal extension sends the status information of the digital
inputs to the controller.

Basis identifier: 767

ƒ

PDO−RX: The terminal extension receives the status information for the
digital outputs from the controller.

Basis identifier: 768

DIP switch

Address

1

2

3

4

5

6

7

8

…

63

1

ON

OFF

ON

OFF

ON

OFF

ON

OFF

...

ON

2

OFF

ON

ON

OFF

OFF

ON

ON

OFF

...

ON

3

OFF

OFF

OFF

ON

ON

ON

ON

OFF

...

ON

4

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

...

ON

5

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

...

ON

6

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

...

ON

ƒ

Set the address of the terminal extension using the DIP switches 1 ... 6.