Commissioning
Configuration with internal DIP switches
Settings in the operating mode (normal operation)
l
62
EDBMZ9374X DE/EN/FR 4.2
)
Note!
Note that the address of the terminal extension must one value
higher than the address of the controller.
ƒ
In the Lenze default setting, the master has address 1 (C0350 = 1).
In this case, set the terminal extension to address 2.
Number of terminal extensions used
9374
9374
9374
9374
CAN
CAN
CAN
CAN
CAN
9374-Master
9374-Slave1
9374-Slave2
9374-Slave3
Slave
Master
9374_012
ƒ
The terminal extension 9374−master communicates with the controller
(master).
ƒ
Three more terminal extensions can communicate with the 9374−master
as slaves via the system bus.
DIP switch
Number of terminal extensions
1*
2
3
4
7
OFF
ON
OFF
ON
8
OFF
OFF
ON
ON
*
Terminal extension is always "9374−master"