Commissioning

Code table

7

l

66

EDBMZ9374X DE/EN/FR 4.2

7.5

Code table

How to read the code table

Column

Abbreviation

Meaning

Code

Cxxxx

Code Cxxxx

Parameter value accepted immediately
(ONLINE)

1

Subcode 1 of Cxxxx

2

Subcode 2 of Cxxxx

[Cxxxx]

Changed parameter of the code is accepted by switching off the power
supply for the terminal extension

Name

Name of the code

Lenze

Lenze setting (default value)

à

Further information can be obtained from "IMPORTANT"

Selection

1

{%}

99 Min. value

{unit} Max. value

IMPORTANT

Brief, important explanations

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

[C0010] I/O reversal

0

Bit 0 ... bit 7
Bit 8 ... bit 15
Bit 16 ... bit 23
Bit 24 ... bit 31

Inputs/Outputs 9374 master
Inputs/Outputs 9374 slave1
Inputs/Outputs 9374 slave2
Inputs/Outputs 9374 slave3

32 bit information
Configuration of the
digital inputs/outputs

Bit value 0
Bit value 1

Input
Output

C0011

Debouncing
time

1

1

{1 msec}

255 Delay for the data

acceptance at the digital
inputs

C0012

Switching off
event
transmission

1

Bit 0 ... bit 7
Bit 8 ... bit 15
Bit 16 ... bit 23
Bit 24 ... bit 31

Inputs/Outputs 9374 master
Inputs/Outputs 9374 slave1
Inputs/Outputs 9374 slave2
Inputs/Outputs 9374 slave3

Bit value 0
Bit value 1

Cyclic transmission
Event−triggered transmission

C0014

Higher−level
transmission
cycle

100

100

{1 msec}

65000 Independent of the

setting in C0015

C0015

Minimum
transmission
break

0

0

{1 msec}

255 Effective only with

event−triggered process
data transmission.
Long transmission breaks
reduce the bus load.

0 = no transmission break

C0030

Monitoring
output
terminals

0

0

{100 ms}

25500 If a communication error

has occurred and the
monitoring time has
elapsed, the digital
outputs change to LOW
level.

0 = no monitoring