Commissioning

Code table

7

l

67

EDBMZ9374X DE/EN/FR 4.2

IMPORTANT

Possible settings

Code

IMPORTANT

Selection

Lenze

Name

No.

[C0050] BasisId CAN−IN

(dig. OUT)

768

384

{1}

896 CAN bus identifier for the

process data message
PDO−RX (controller

®

terminal extension)

[C0051] BasisId

CAN−OUT (dig.
IN)

767

384

{1}

896

CAN bus identifier for the
process data message
PDO−TX (terminal
extension

® controller)

C0093

DIS: Controller
identification

93740000 = terminal extension 9374

Only display
Code is supported as
from version
33.9374IB.1A.10

C0099

DIS: Software
version

1000 = Software version 1.0

Only display
Code is supported as
from version
33.9374IB.1A.10

C0102

Identification
of additional
modules

Identified modules (9474 slave)

Only display
(hexadecimal)
16 bit information
Will only be displayed
after the code has been
read

0000

h

0001

h

0002

h

0003

h

0004

h

0005

h

0006

h

0007

h

No module identified
Module no. 1 (9374 slave1)
Module no. 2 (9374 slave2)
Module no. 1 and 2 (9374 slave1 and 2)
Module no. 3 (9374 slave3)
Module no. 1 and 3 (9374 slave1 and 3)
Module no. 2 and 3 (9374 slave2 and 3)
Module no. 1, 2 and 3 (9374 slave1, 2 and
3)

C0104

I/O signal level

Bit 0 ... bit 7
Bit 8 ... bit 15
Bit 16 ... bit 23
Bit 24 ... bit 31

Inputs/Outputs 9374 master
Inputs/Outputs 9374 slave1
Inputs/Outputs 9374 slave2
Inputs/Outputs 9374 slave3

Only display
(hexadecimal)
32 bit information
Status of inputs/outputs
Code is supported as
from version
33.9374IB.1A.10

Bit value 0
Bit value 1

LOW signal
HIGH signal

C0202

Internal device
identification
Code is supported as
from version
33.9374IB.1A.10

1 Product code 1

2 Product code 2

3 Product code 3

4 Product code 4

Advertising