7applications – Lenze DSD User Manual
Page 190

7
Applications
7.21
Dimension the multi-axis system
190
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.21.2.5
Decentralised mains supply via regenerative power supply modules and inverters
[7-191] Decentralised mains supply via regenerative power supply modules and inverters
• The regenerative power supply module increases the power of the drive in motor mode (reason-
able for e.g. hoist drives).
• The regenerative power is not increased.
• The arrangement cannot be dimensioned in the DSD.
• The regenerative power supply module and the drive axis can be each dimensioned separate-
ly in the DSD.
• The parallel connection must be calculated manually. The required intermediate results are
provided by DSD.
• The entire power balance must be calculated manually.
3 AC
DC bus
M
3~
2
2
3
3
3
3
3
=
~
=
~
=
~