7 motor components, 1 feedback selection, Feedback selection – Lenze DSD User Manual
Page 357: 11 drive dimensioning

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
357
11
Drive Dimensioning
11.7
Motor components
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.7
Motor components
11.7.1
Feedback selection
When the selection is made, DSD checks whether
• the design of the feedback system is compatible with the selected motor,
• the function of the feedback system is compatible with the selected inverter,
• the inverter may be operated without feedback.
Tip!
You can also configure feedback systems for motors which act on slave drives. They there-
fore do not have to be compatible to the inverter that controls the motor.
The following criteria must be checked manually:
• Accuracies, resolutions, limit frequencies, max. permissible speeds etc.
• The limit frequency at the inverter input can be exceeded if the feedback system outputs a
too high pulse frequency due to the combination of number of increments and max. speed.