12 downtime 2, 13 downtime 3, Downtime 2 – Lenze DSD User Manual
Page 222: Downtime 3, 7applications

7
Applications
7.22
Winding drive for rewinder/unwinder
222
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.22.7.12 Downtime 2
7.22.7.13 Downtime 3
Parameter
Description
t
0.2
Downtime after the deceleration phase while the max. tensile force F
max
still acts on the wind-
ing material.
• Condition: CINH = 0
CINH
Controller locked
F
Tensile force of the winding drive
T
Cycle of one winding process
t
0.1
t
0.2
Downtime 2
t
0.3
v
Line speed
T
v
t
t
0,1
t
0,2
t
0,3
F
t
1
t
CINH
Parameter
Description
t
0.3
Downtime after the winding process during which no tensile force (F
max
= 0) acts on the wind-
ing material.
• The controller is always inhibited during downtime 3. The thermal load of the inverter and
the motor is reduced.
CINH
Controller locked
F
Tensile force of the winding drive
T
Cycle of one winding process
t
0.1
t
0.2
t
0.3
Downtime 3
v
Line speed
T
v
t
t
0,1
t
0,2
t
0,3
F
t
1
t