4 intermittent load s6, s7, Intermittent load s6, s7, 8motion design – Lenze DSD User Manual
Page 273

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
273
8
Motion design
8.3
Predefined motion profile according to operating mode
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3.4
Intermittent load S6, S7
Operation composed of a sequence of identical cycles each of which including an operating time
with constant load and an idle time. There is no idle time.
[8-12] Motion profile for operating mode S6
ED
t
t
t
acc
t
dec
Description
t
Cycle time, corresponds to the duration of the load phase.
t
acc
Acceleration time required by the drive until the constant load condition is reached.
t
dec
Deceleration time required by the drive until standstill.
OT
Relative operating time
• Percentage ratio of duration of load phase to duration of no-load phase.