7applications – Lenze DSD User Manual
Page 78

7
Applications
7.3
Belt drive, rotating
78
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[7-23] Equation 14: Constant torque loss
The torque loss depends on the torque M
D
which is to be transmitted, so that the resulting torque
M
App
defining the power of the application is calculated via the following equation.
• The deterioration of the efficiency within operation in generator mode (backward efficiency) is
considered during this calculation.
[7-24] Equation 15: Required torque of the application
Tip!
Further equations to complete the calculations required for an application can be found in
the chapter "
".
M
th
1
η
Blt
---------
1
–
max M
D
(
)
⋅
=
M
App
M
D
ω
ω
-------
M
th
⋅
+
J
Cog
α
⋅
+
=