18 drive dimensioning messages – Lenze DSD User Manual
Page 464

18
Drive dimensioning messages
18.7
Feedback
464
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.7.4
Feedback system for safety-oriented applications is not checked
Note!
The feedback system selected is suitable for safety-oriented applications.
DSD does not check whether the inverter supports this functionality.
Make sure that an inverter with implemented safety functions (e. g. "Safely limited speed") is used. Servo
Drives 9400 support the safety functions, e.g. by means of the SM301 safety module.
Cause
Effects
Possible remedies
DSD does not check whether the in-
verter supports safety functions.
The desired safety functions are not
guaranteed.
For Servo Drives 9400, select the
SM301 safety module in the product
options.