3 decentralised inverters, 10 structure of the drive axis, 3 drive concept 298 – Lenze DSD User Manual

Page 298

Advertising
background image

10

Structure of the drive axis

10.3

Drive concept

298

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.3.4.3

Decentralised inverters

8400 motec

8400 protec

Illustration

Short description

Frequency inverters for motor and wall mounting, V/f

control without encoder, vector control without speed

feedback, optionally with integrated safety functions,

fieldbus communication, pluggable memory chip for

the parameter set, high operational reliability thanks to

a thermally independent system

Frequency inverter for wall mounting, vector control

with and without speed feedback, overload capacity up

to 180 %, optionally with integrated safety functions,

fieldbus communication, pluggable memory chip for

the parameter set, high operational reliability thanks to

a thermally independent system

Voltage range/power range

3 AC 320 … 528 V: 0.37 … 7.5 kW

3 AC 320 … 550 V:

0.75 … 4.0 kW (1st version)

7.5 kW (2nd version)

Approvals

CE (UL in preparation)

CE (UL in preparation)

Permissible power systems

TN, TT, IT

TN, TT

Switching frequencies

4, 8, 16 kHz

2, 4, 8, 16 kHz

Mechanical design

Built-in unit

–

–

Push-through technique

–

–

Cold plate technique

–

–

Motor mounting

–

Wall mounting

Enclosure

IP 55 / IP 66

IP 65

Operation in generator mode

Integrated brake resistor

External brake transistor

–

–

Regenerative

–

–

Control types

V/f control

Vector control (encoderless)

Servo control

–

Drive function

Voltage / frequency control

Torque control

–

Closed-loop speed control

PID controller

Motion Control

–

–

Programmability

Parameterisation

Function block programming

–

IEC 61131-3

–

–

I/O

Analog input / output

0/0 or 1/0

1/0

Digital input / output

2/0 or 5/1

4/2 or 6/0

Relay output

–

Speed feedback

–

PTC

KTY

–

–