2 mounting position, 11 drive dimensioning – Lenze DSD User Manual
Page 309

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
309
11
Drive Dimensioning
11.1
Preselection of the geared motor
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.1.2
Mounting position
The Continuous rated curve of the gearbox is significantly affected by the mounting position.
GST
GFL
GKS
Position of terminal box: 2, 3, 4, 5
Without terminal box: 0
Solid shaft: 6
Foot: 3, 4
Position of terminal box: 2, 3, 4, 5
Hollow shaft: 0
Without foot: 0
Without terminal box: 0
Hollow shaft with shrink disk: 1, 6
Solid shaft: 3, 5, 3+5
Flange: 3, 5, 3+5
Position of terminal box: 2, 3, 4, 5
Hollow shaft: 0
Without flange: 0
Without terminal box: 0
Hollow shaft with shrink disk: 3, 5