18.10.9
Utilisation of the power supply module is >100 %
Warning!
The utilisation of the power supply module relating to the pulse power in the DC bus is xxx %. Thus, the
limit value of 100 % is exceeded.
Cause
Effects
Possible remedies
The power supply module is actuated
in overload operation for too long.
Operation is not permissible. The de-
vice is overloaded.
• Select larger power supply mod-
ule.
• Connect several power supply
modules in parallel.
• Observe notes in the documen-
tation of the power supply