Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 12

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

40

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V

Xtra-Guard® 1

High Performance

300 V Foil Shielded, Multiconductor

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart E

(page 520)

• 20, 18, 16 AWG: Chart D (page 519)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Aluminum/polyester foil shield,

with 25% overlap and foil

facing inward

• Tinned copper drain wire sized

the same as cable conductors

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5382C

2

0.230

5.84

0.032

0.81

5382/1C*

2

0.230

5.84

0.032

0.81

5383C

3

0.242

6.15

0.032

0.81

5383/1C*

3

0.242

6.15

0.032

0.81

5384C

4

0.263

6.68

0.032

0.81

5386C

6

0.311

7.90

0.032

0.81

5388C

8

0.336

8.53

0.032

0.81

5390C

10

0.388

9.86

0.032

0.81

5390/15C

15

0.437

11.10

0.032

0.81

5390/20C

20

0.488

12.40

0.032

0.81

5390/25C

25

0.588

14.94

0.053

1.35

5390/30C

30

0.621

15.77

0.053

1.35

5390/40C

40

0.692

17.58

0.053

1.35

5390/50C

50

0.762

19.35

0.053

1.35

5390/60C

60

0.885

22.48

0.083

2.11

*Conductors color-coded per international standards: brown, blue, green/yellow.

16 AWG (1.23 mm

2

)

Stranding: 19/0.0117 (19 x 0.29 mm)

Insulation thickness: 0.016 (0.41 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5362C

2

0.254

6.45

0.032

0.81

5362/1C*

2

0.254

6.45

0.032

0.81

5363C

3

0.268

6.81

0.032

0.81

5363/1C*

3

0.268

6.81

0.032

0.81

5364C

4

0.292

7.42

0.032

0.81

5366C

6

0.347

8.81

0.032

0.81

5368C

8

0.376

9.55

0.032

0.81

5370C

10

0.436

11.07

0.032

0.81

5370/15C

15

0.492

12.50

0.032

0.81

5370/20C

20

0.593

15.06

0.053

1.35

5370/25C

25

0.660

16.76

0.053

1.35

5370/30C

30

0.698

17.73

0.053

1.35

5370/40C

40

0.779

19.79

0.083

2.11

*Conductors color-coded per international standards: brown, blue, green/yellow.

Advertising