Xtra-guard® standard flex – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 81

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

109

Cable > Xtra-Guard > Xtra-Guard Flex > Multiconductor > Shielded > 600 V

Xtra-Guard® Standard Flex

Light to Moderate Flex Applications

600 V Shielded, Multiconductor

UL AWM 2587

CSA AWM I/II A/B FT1

CE

Operating Temperature

• –5°C to +90°C (flexing)

• –40°C to +90°C (stationary)

Conductor Color Coding

• Numbered black conductors

• 1 yellow/green ground

conductor

• Jacket color: slate

Materials

• Finely stranded bare copper

conductors

• Lubricated PVC Insulation

• Oil-resistant PVC jacket

• Tinned copper braid shield,

85% coverage

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-FLEX: Highly flexible,

cross-linked silicone rubber

• FIT-650: Chemical/

temperature resistant cross-

linked fluoroelastomer

20 AWG (0.51 mm

2

)

Stranding: 10/30 (10 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

65003CY

3

0.339

8.61

0.035

0.89

65007CY

7

0.409

10.39

0.035

0.89

65012CY

12

0.521

13.23

0.040

1.02

65025CY

25

0.712

18.08

0.050

1.27

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

65803CY

3

0.360

9.14

0.035

0.89

65804CY

4

0.384

9.75

0.035

0.89

65805CY

5

0.414

10.52

0.035

0.89

65807CY

7

0.439

11.15

0.035

0.89

65812CY

12

0.568

14.43

0.045

1.14

65818CY

18

0.671

17.04

0.053

1.35

65825CY

25

0.776

19.71

0.053

1.35

16 AWG (1.32 mm

2

)

Stranding: 26/30 (26 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

65603CY

3

0.388

9.86

0.035

0.89

65604CY

4

0.416

10.57

0.035

0.89

65605CY

5

0.449

11.40

0.035

0.89

65607CY

7

0.484

12.29

0.035

0.89

65612CY

12

0.640

16.26

0.052

1.32

65618CY

18

0.767

19.48

0.062

1.57

65625CY

25

0.901

22.89

0.067

1.70

14 AWG (2.08 mm

2

)

Stranding: 41/30 (41 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

65403CY

3

0.443

11.25

0.042

1.07

65404CY

4

0.486

12.34

0.047

1.19

65405CY

5

0.537

13.64

0.052

1.32

65407CY

7

0.581

14.76

0.057

1.45

65412CY

12

0.732

18.59

0.062

1.57

65418CY

18

0.890

22.61

0.083

2.11

Advertising