Xtra-guard® continuous flex control – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 83

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

111

Cable > Xtra-Guard > Xtra-Guard Flex > Multiconductor > Unshielded > 600 V

Xtra-Guard® Continuous Flex Control

C-Track or High Flexing Applications Up to 14 Million Flex Life Cycles

600 V Unshielded, Multiconductor

UL AWM 2587

CSA AWM I/II A/B FT1

CE

Operating Temperature

• -5°C to +90°C (flexing)

• -40°C to +90°C (stationary)

Conductor Color Coding

• Numbered red conductors

• 1 yellow/green ground

conductor

• Jacket color: black

Materials

• Finely stranded tinned copper

conductors

• Lubricated PVC insulation

• Oil-resistant PVC jacket

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-FLEX: Highly flexible,

cross-linked silicone rubber

• FIT-650: Chemical/

temperature resistant cross-

linked fluoroelastomer

20 AWG ( 0.51 mm

2

)

Stranding: 63/38 (63 x 0.10 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85003

3

0.272

6.91

0.035

0.89

85004

4

0.297

7.54

0.035

0.89

85005

5

0.323

8.20

0.035

0.89

85007

7

0.388

9.86

0.040

1.02

85012

12

0.460

11.68

0.045

1.14

85018

18

0.548

13.92

0.050

1.27

85025

25

0.691

17.55

0.065

1.65

85034

34

0.746

18.95

0.065

1.65

18 AWG (0.85 mm

2

)

Stranding: 105/38 (105 x 0.10 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85803

3

0.298

7.57

0.035

0.89

85804

4

0.326

8.28

0.035

0.89

85805

5

0.355

9.02

0.035

0.89

85807

7

0.438

11.13

0.045

1.14

85812

12

0.520

13.21

0.050

1.27

85815

15

0.577

14.66

0.050

1.27

85818

18

0.608

15.44

0.050

1.27

85825

25

0.767

19.48

0.065

1.65

85834

34

0.830

21.08

0.065

1.65

16 AWG (1.36mm

2

)

Stranding: 168/38 (168 x 0.10 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85603

3

0.331

8.41

0.035

0.89

85604

4

0.362

9.19

0.035

0.89

85605

5

0.396

10.06

0.035

0.89

85607

7

0.478

12.14

0.040

1.02

85612

12

0.573

14.55

0.045

1.14

85618

18

0.674

17.12

0.045

1.14

85625

25

0.862

21.89

0.065

1.65

85634

34

0.936

23.77

0.065

1.65

85650

50

1.161

29.49

0.085

2.16

14 AWG (2.16mm

2

)

Stranding: 266/38 (266 x 0.10 mm)

Insulation thickness: 0.022” (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85404

4

0.424

10.77

0.050

1.27

85407

7

0.582

14.78

0.070

1.78