Xtra-guard® standard flex – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 78

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

106

Cable > Xtra-Guard > Xtra-Guard Flex > Multiconductor > Unshielded > 600 V

Xtra-Guard® Standard Flex

Light to Moderate Flex Applications

600 V Unshielded, Multiconductor

UL AWM 2587

CSA AWM I/II A/B FT1

CE

Operating Temperature

• –5°C to +90°C (flexing)

• –40°C to +90°C (stationary)

Conductor Color Coding

• Numbered black conductors

• 1 yellow/green ground

conductor (3 conductor

and greater)

• Jacket color: slate

Materials

• Finely stranded bare copper

conductors

• Lubricated PVC insulation

• Oil-resistant PVC jacket

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-FLEX: Highly flexible,

cross-linked silicone rubber

• FIT-650: Chemical/

temperature resistant cross-

linked

fluoroelastomer

20 AWG (0.51 mm

2

)

Stranding: 10/30 (10 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

65002

2

0.238

6.05

0.035

0.89

65003

3

0.251

6.38

0.035

0.89

65004

4

0.272

6.91

0.035

0.89

65005

5

0.305

7.75

0.038

0.97

65007

7

0.327

8.31

0.038

0.97

65009

9

0.416

10.57

0.040

1.02

65012

12

0.433

11.00

0.045

1.14

65018

18

0.527

13.39

0.055

1.40

65025

25

0.615

15.62

0.055

1.40

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

65802

2

0.258

6.55

0.035

0.89

65803

3

0.272

6.91

0.035

0.89

65804

4

0.296

7.52

0.035

0.89

65805

5

0.326

8.28

0.035

0.89

65807

7

0.351

8.92

0.035

0.89

65809

9

0.445

11.30

0.035

0.89

65812

12

0.470

11.94

0.043

1.09

65818

18

0.567

14.40

0.050

1.27

65825

25

0.666

16.92

0.050

1.27

65834

34

0.769

19.53

0.060

1.52

65841

41

0.835

21.21

0.063

1.60

65850

50

0.967

24.56

0.083

2.11

16 AWG (1.32 mm

2

)

Stranding: 26/30 (26 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

65602

2

0.284

7.21

0.035

0.89

65603

3

0.300

7.62

0.035

0.89

65604

4

0.328

8.33

0.035

0.89

65605

5

0.361

9.17

0.035

0.89

65607

7

0.390

9.91

0.035

0.89

65609

9

0.509

12.93

0.041

1.04

65612

12

0.536

13.61

0.049

1.24

65618

18

0.632

16.05

0.050

1.27

65625

25

0.756

19.20

0.055

1.40

65641

41

0.959

24.36

0.075

1.90

65650

50

1.079

27.41

0.083

2.11

Advertising