Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

61

Cable > Xtra-Guard > Xtra-Guard 2 > Multiconductor > Foil Shielded > 300 V

Xtra-Guard® 2

Oil and Abrasion Resistant

300 V Foil Shielded, Multiconductor

UL AWM 20668 VW-1

CSA AWM I/II A/B FT1

Operating Temperature

• –30°C to +90°C

Conductor Color Coding

• 24, 22 AWG: Chart E (page 520)

• 20, 18, 16 AWG: Chart D

(page 519)

• Nine jacket colors

(black standard)

• Custom colors available

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Specially formulated

polyurethane jacket

• UV resistant

• Aluminum/polyester/aluminum

foil shield, with 25% overlap and

foil facing inward

• Tinned copper drain wire sized

the same as cable conductors

• Nylon ripcord

Availability

Made to order

1000 ft (305 m) minimum

FIT® Tubing Recommendations

• FIT-750: Bonding adhesive lined,

cross-linked polyolefin

24 AWG (0.23 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

25092

2

0.160

4.06

0.032

0.81

25093

3

0.167

4.24

0.032

0.81

25094

4

0.179

4.55

0.032

0.81

25096

6

0.205

5.21

0.032

0.81

25098

8

0.219

5.56

0.032

0.81

25100

10

0.248

6.30

0.032

0.81

25100/15

15

0.275

6.99

0.032

0.81

25100/20

20

0.304

7.72

0.032

0.81

25100/25

25

0.336

8.53

0.032

0.81

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

25192

2

0.172

4.37

0.032

0.81

25193

3

0.180

4.57

0.032

0.81

25194

4

0.193

4.90

0.032

0.81

25196

6

0.223

5.66

0.032

0.81

25198

8

0.239

6.07

0.032

0.81

25199/10

10

0.272

6.91

0.032

0.81

25199/15

15

0.303

7.70

0.032

0.81

25199/20

20

0.335

8.51

0.032

0.81

25199/25

25

0.372

9.45

0.032

0.81

25199/30

30

0.393

9.98

0.032

0.81

25199/40

40

0.438

11.13

0.032

0.81

25199/50

50

0.482

12.24

0.032

0.81

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32

mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

25462

2

0.212

5.38

0.032

0.81

25463

3

0.223

5.66

0.032

0.81

25464

4

0.242

6.15

0.032

0.81

25466

6

0.284

7.21

0.032

0.81

25468

8

0.306

7.77

0.032

0.81

25470

10

0.352

8.94

0.032

0.81

25470/15

15

0.395

10.03

0.032

0.81

25470/20

20

0.441

11.20

0.032

0.81

25470/25

25

0.492

12.50

0.032

0.81

25470/30

30

0.521

13.23

0.032

0.81

25470/40

40

0.626

15.90

0.053

1.35

25470/50

50

0.688

17.48

0.053

1.35

Advertising