Xtra-guard® 1, High performance 300 v unshielded, multiconductor – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 4

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

32

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Unshielded > 300 V

Xtra-Guard® 1

High performance

300 V Unshielded, Multiconductor

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart E

(page 520)

• 20, 18, 16 AWG: Chart D

(page 519)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned

copper conductors

• Premium PVC insulation

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

24 AWG (0.23 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5012C

2

0.156

3.96

0.032

0.81

5013C

3

0.163

4.14

0.032

0.81

5014C

4

0.175

4.45

0.032

0.81

5016C

6

0.201

5.11

0.032

0.81

5018C

8

0.215

5.46

0.032

0.81

5020C

10

0.244

6.20

0.032

0.81

5020/15C

15

0.271

6.88

0.032

0.81

5020/20C

20

0.300

7.62

0.032

0.81

5020/25C

25

0.332

8.43

0.032

0.81

5020/30C

30

0.350

8.89

0.032

0.81

5020/40C

40

0.390

9.91

0.032

0.81

5020/50C

50

0.429

10.90

0.032

0.81

28 AWG (0.09 mm

2

)

Stranding: 7/36 (7 x 0.127

mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5920

2

0.138

3.51

0.032

0.81

5921

3

0.144

3.66

0.032

0.81

5922

4

0.153

3.89

0.032

0.81

5923

6

0.174

4.42

0.032

0.81

5924

7

0.174

4.42

0.032

0.81

5925

8

0.185

4.70

0.032

0.81

26 AWG (0.14 mm

2

)

Stranding: 7/34 (7 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5666

2

0.146

3.71

0.032

0.81

5667

3

0.152

3.86

0.032

0.81

5668

4

0.162

4.11

0.032

0.81

5669

6

0.186

4.72

0.032

0.81

5670

7

0.186

4.72

0.032

0.81

5671

8

0.198

5.03

0.032

0.81

5672

10

0.224

5.69

0.032

0.81

5673

15

0.248

6.30

0.032

0.81

Advertising