Xtra-guard® 5 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 68

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

96

Cable > Xtra-Guard > Xtra-Guard 5 > Multiconductor > Unshielded > 300 V

Xtra-Guard® 5

Maximum Temperature and Chemical Performance

300 V Unshielded, Multiconductor

UL AWM 20229

UL CMP

CSA CMP FT6

Operating Temperature

• –80°C to +200°C

• –80°C to +150°C (AWM, CMP)

Conductor Color Coding

• Chart E (page 520)

• Nine jacket tints (tan standard)

• Custom colors available

Materials

• Stranded tinned copper

conductors

• FEP insulation

• FEP jacket

• Aramid fiber ripcord

Availability

Made to order

1000 ft (305 m) minimum

FIT® Tubing Recommendations

• FIT-650: Chemical/temperature

resistant flexible fluoroelastomer

• FIT-400: Temperature/chemical

resistant FEP

18 AWG (0.90 mm

2

)

Stranding: 7/26 (7 x 0.40 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

55062

2

0.196

4.98

0.027

0.69

55063

3

0.207

5.26

0.027

0.69

55064

4

0.225

5.72

0.027

0.69

55066

6

0.265

6.73

0.027

0.69

55069

9

0.307

7.80

0.027

0.69

55070/12

12

0.343

8.71

0.027

0.69

16 AWG (1.23 mm

2

)

Stranding: 19/0.0117 (19 x 0.29 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

55072

2

0.218

5.54

0.027

0.69

55073

3

0.230

5.84

0.027

0.69

55074

4

0.251

6.38

0.027

0.69

55076

6

0.298

7.57

0.027

0.69

55079

9

0.347

8.81

0.027

0.69

55080/12

12

0.388

9.86

0.027

0.69

Advertising