Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 27

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

55

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5121C

1

0.196

4.98

0.032

0.81

5122C

2

0.260

6.60

0.032

0.81

5123C

3

0.273

6.93

0.032

0.81

5124C

4

0.295

7.49

0.032

0.81

5125C

5

0.319

8.10

0.032

0.81

5126C

6

0.344

8.74

0.032

0.81

5129C

9

0.396

10.06

0.032

0.81

5129/11C

11

0.424

10.77

0.032

0.81

5129/15C

15

0.475

12.07

0.032

0.81

5129/19C

19

0.507

12.88

0.032

0.81

5129/27C

27

0.649

16.48

0.053

1.35

Cable > Xtra-Guard > Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V

Xtra-Guard® 1

High Performance

300 V Supra-Shield® Foil/Braid, Multipair

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart B

(page 516)

• 20, 18 AWG: Chart A (page 516)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Supra-Shield foil + braid shield:

Aluminum/polyester/aluminum

foil with 25% overlap min.

Tinned copper drain wire sized

the same as conductors

Tinned copper braid, 70%

coverage min.

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5292C

2

0.326

8.28

0.032

0.81

5293C

3

0.344

8.74

0.032

0.81

5296C

6

0.443

11.25

0.032

0.81

5299C

9

0.515

13.08

0.032

0.81

5299/19C

19

0.719

18.26

0.053

1.35

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5132C

2

0.355

9.02

0.032

0.81

5133C

3

0.376

9.55

0.032

0.81

5136C

6

0.488

12.40

0.032

0.81

5139C

9

0.611

15.52

0.053

1.35

5139/27C

27

1.004

25.50

0.083

2.11

Advertising