Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 19

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

47

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V

Xtra-Guard® 1

High Performance

300 V Supra-Shield® Foil/Braid, Multiconductor

UL CM

UL AWM 2343 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• Chart E (page 520)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Supra-Shield foil + braid shield:

Aluminum/polyester/aluminum

foil with 25% overlap min.

Tinned copper drain wire sized

the same as conductors

Tinned copper braid, 70%

coverage min.

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

24 AWG (0.23 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5300C

5

0.278

7.06

0.063

1.60

5301C

7

0.291

7.39

0.063

1.60

5302C

12

0.341

8.66

0.063

1.60

5303C

15

0.361

9.17

0.063

1.60

5304C

19

0.378

9.60

0.063

1.60

5305C

27

0.429

10.90

0.063

1.60

5306C

37

0.466

11.84

0.063

1.60

5307C

48

0.517

13.13

0.063

1.60

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5310C

5

0.294

7.47

0.063

1.60

5311C

7

0.309

7.85

0.063

1.60

5312C

12

0.366

9.30

0.063

1.60

5313C

15

0.389

9.88

0.063

1.60

5314C

19

0.408

10.36

0.063

1.60

5316C

37

0.508

12.90

0.063

1.60

5318C

60

0.608

15.44

0.063

1.60

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

Mm

5320/4C

4

0.299

7.59

0.063

1.60

5320C

5

0.316

8.03

0.063

1.60

5321C

7

0.333

8.46

0.063

1.60

5322C

12

0.399

10.13

0.063

1.60

5323C

15

0.426

10.82

0.063

1.60

5324C

19

0.448

11.38

0.063

1.60

5325C

27

0.515

13.08

0.063

1.60

5326C

37

0.564

14.33

0.063

1.60

Advertising