Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

115

Cable > Xtra-Guard > Xtra-Guard Flex > Multiconductor > Unshielded > 300 V

Xtra-Guard® Continuous Flex Data

C-Track or High Flexing Applications Up to 6 Million Flex Life Cycles

300 V Unshielded, Multiconductor

UL CM

UL AWM 2661

CSA AWM I/II A/B FT4

CSA CMG

CE

Operating Temperature

• +5°C to +105°C (flexing)

• -10°C to +105°C (stationary)

Conductor Color Coding

• Chart D (page 519)

• Jacket color: slate

Materials

• Finely stranded tinned copper

conductors

• Lubricated semi-rigid PVC

insulation

• Oil-resistant PVC jacket

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-FLEX: Highly flexible,

cross-linked silicone rubber

• FIT-650: Chemical/

temperature resistant cross-

linked fluoroelastomer

28 AWG (0.09 mm

2

)

Stranding: 7/36 (7 x 0.13 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86002

2

0.154

3.91

0.040

1.02

86003

3

0.160

4.06

0.040

1.02

86004

4

0.170

4.32

0.040

1.02

86005

5

0.180

4.57

0.040

1.02

86007

7

0.203

5.16

0.040

1.02

86012

12

0.263

6.68

0.040

1.02

86018

18

0.262

6.65

0.040

1.02

86025

25

0.309

7.85

0.040

1.02

26 AWG (0.14 mm

2

)

Stranding: 7/34 (7 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86102

2

0.162

4.11

0.040

1.02

86103

3

0.168

4.27

0.040

1.02

86104

4

0.179

4.55

0.040

1.02

86105

5

0.191

4.85

0.040

1.02

86107

7

0.217

5.51

0.040

1.02

86112

12

0.283

7.19

0.040

1.02

86118

18

0.282

7.16

0.040

1.02

86125

25

0.335

8.51

0.040

1.02

24 AWG (0.20 mm

2

)

Stranding: 10/34 (10 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86202

2

0.172

4.37

0.040

1.02

86203

3

0.179

4.55

0.040

1.02

86204

4

0.191

4.85

0.040

1.02

86205

5

0.205

5.21

0.040

1.02

86207

7

0.233

5.92

0.040

1.02

86212

12

0.307

7.80

0.040

1.02

86218

18

0.307

7.80

0.040

1.02

86225

25

0.376

9.55

0.045

1.14

22 AWG (0.38 mm

2

)

Stranding: 19/34 (19 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86302

2

0.188

4.78

0.040

1.02

86303

3

0.197

5.00

0.040

1.02

86304

4

0.211

5.36

0.040

1.02

86305

5

0.227

5.77

0.040

1.02

86307

7

0.260

6.60

0.040

1.02

86312

12

0.347

8.81

0.040

1.02

86318

18

0.347

8.81

0.040

1.02

86325

25

0.426

10.82

0.045

1.14

Advertising