Xtra-guard® 1, High performance 300 v unshielded, multiconductor – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 6

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

34

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Unshielded > 300 V

Xtra-Guard® 1

High Performance

300 V Unshielded, Multiconductor

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart E

(page 520)

• 20, 18, 16 AWG: Chart D

(page 519)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned

copper conductors

• Premium PVC insulation

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5062/1C*

2

0.226

5.74

0.032

0.81

5062C

2

0.226

5.74

0.032

0.81

5063/1C*

3

0.238

6.05

0.032

0.81

5063C

3

0.238

6.05

0.032

0.81

5064C

4

0.259

6.58

0.032

0.81

5066C

6

0.307

7.80

0.032

0.81

5068C

8

0.332

8.43

0.032

0.81

5070C

10

0.384

9.75

0.032

0.81

5070/15C

15

0.433

11.00

0.032

0.81

5070/20C

20

0.484

12.29

0.032

0.81

5070/25C

25

0.542

13.77

0.032

0.81

5070/30C

30

0.617

15.67

0.053

1.35

5070/40C

40

0.688

17.48

0.053

1.35

5070/50C

50

0.758

19.25

0.053

1.35

5070/60C

60

0.881

22.38

0.083

2.11

16 AWG (1.23 mm

2

)

Stranding: 19/0.0117 (19 x 0.29 mm)

Insulation thickness: 0.016 (0.41 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5072/1C*

2

0.250

6.35

0.032

0.81

5072C

2

0.250

6.35

0.032

0.81

5073/1C*

3

0.264

6.71

0.032

0.81

5073C

3

0.264

6.71

0.032

0.81

5074C

4

0.288

7.32

0.032

0.81

5076C

6

0.343

8.71

0.032

0.81

5078C

8

0.372

9.45

0.032

0.81

5080C

10

0.432

10.97

0.032

0.81

5080/15C

15

0.488

12.40

0.032

0.81

5080/20C

20

0.547

13.89

0.053

0.81

5080/25C

25

0.656

16.66

0.053

0.81

5080/30C

30

0.694

17.63

0.053

0.81

5080/40C

40

0.775

19.69

0.083

2.11

5080/50C

50

0.917

23.29

0.083

2.11

*Conductors color-coded per international standards: brown, blue, green/yellow.

*Conductors color-coded per international standards: brown, blue, green/yellow.

Advertising