Cable > Xtra-Guard > Xtra-Guard Flex > Multiconductor > Foil/Spiral Shield > 300 V

Xtra-Guard® Continuous Flex Data

C-Track or High Flexing Applications Up to 6 Million Flex Life Cycles

300 V Foil/Spiral Shield, Multiconductor

UL CM

UL AWM 2661

CSA AWM I/II A/B FT4

CSA CMG

CE

Operating Temperature

• +5°C to 105°C (flexing)

• -10°C to 105°C (stationary)

Conductor Color Coding

• Chart D (page 519)

• Jacket color: slate

Materials

• Finely stranded tinned copper

conductors

• Lubricated semi-rigid PVC

insulation

• Foil +spiral shield

Aluminum/polyester foil shield,

25% overlap min.

Foil facing outward

Tinned copper spiral shield,

90% coverage

• Oil-resistant PVC jacket

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-FLEX: Highly flexible,

cross-linked silicone rubber

• FIT-650: Chemical/

temperature resistant cross-

linked fluoroelastomer

28 AWG (0.09 mm

2

)

Stranding: 7/36 (7 x 0.13 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86002CY

2

0.174

4.42

0.040

1.02

86003CY

3

0.180

4.57

0.040

1.02

86004CY

4

0.190

4.83

0.040

1.02

86005CY

5

0.200

5.08

0.040

1.02

86007CY

7

0.223

5.66

0.040

1.02

86012CY

12

0.283

7.19

0.040

1.02

86018CY

18

0.282

7.16

0.040

1.02

86025CY

25

0.329

8.36

0.040

1.02

26 AWG (0.14 mm

2

)

Stranding: 7/34 (7 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86102CY

2

0.182

4.62

0.040

1.02

86103CY

3

0.188

4.78

0.040

1.02

86104CY

4

0.199

5.05

0.040

1.02

86105CY

5

0.211

5.36

0.040

1.02

86107CY

7

0.237

6.02

0.040

1.02

86112CY

12

0.303

7.70

0.040

1.02

86118CY

18

0.302

7.67

0.040

1.02

86125CY

25

0.355

9.02

0.040

1.02

24 AWG (0.20 mm

2

)

Stranding: 10/34 (10 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86202CY

2

0.192

4.88

0.040

1.02

86203CY

3

0.199

5.05

0.040

1.02

86204CY

4

0.211

5.36

0.040

1.02

86205CY

5

0.225

5.72

0.040

1.02

86207CY

7

0.253

6.43

0.040

1.02

86212CY

12

0.327

8.31

0.040

1.02

86218CY

18

0.327

8.31

0.040

1.02

86225CY

25

0.396

10.06

0.045

1.14

22 AWG (0.38 mm2)

Stranding: 19/34 (19 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

86302CY

2

0.208

5.28

0.040

1.02

86303CY

3

0.217

5.51

0.040

1.02

86304CY

4

0.231

5.87

0.040

1.02

86305CY

5

0.247

6.27

0.040

1.02

86307CY

7

0.280

7.11

0.040

1.02

86312CY

12

0.367

9.32

0.040

1.02

86318CY

18

0.367

9.32

0.040

1.02

86325CY

25

0.446

11.33

0.045

1.14

Advertising