Xtra-guard® 1, High performance 300 v foil shield, multipair – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 25

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

53

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5481C

1

0.172

4.37

0.032

0.81

5482C

2

0.236

5.99

0.032

0.81

5483C

3

0.249

6.32

0.032

0.81

5484C

4

0.271

6.88

0.032

0.81

5485C

5

0.295

7.49

0.032

0.81

5486C

6

0.320

8.13

0.032

0.81

5489C

9

0.372

9.45

0.032

0.81

5489/11C

11

0.400

10.16

0.032

0.81

5489/15C

15

0.451

11.46

0.032

0.81

5489/19C

19

0.483

12.27

0.032

0.81

5489/27C

27

0.619

15.72

0.053

1.35

Cable > Xtra-Guard > Xtra-Guard 1 > Multipair > Foil Shield > 300 V

Xtra-Guard® 1

High Performance

300 V Foil Shield, Multipair

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart B

(page 516)

• 20, 18 AWG: Chart A (page 516)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Aluminum/polyester foil shield,

with 25% overlap and foil

facing inward

• Tinned copper drain wire sized

the same as cable conductors

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5452C

2

0.302

7.67

0.032

0.81

5453C

3

0.320

8.13

0.032

0.81

5456C

6

0.419

10.64

0.032

0.81

5459C

9

0.491

12.47

0.032

0.81

5459/12C

12

0.549

13.94

0.032

0.81

5459/19C

19

0.689

17.50

0.053

1.35

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5373C

3

0.352

8.94

0.032

0.81

5376C

6

0.464

11.79

0.032

0.81

Advertising