Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 14

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

42

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Foil Shielded > 600 V

Xtra-Guard® 1

High Performance

600 V Foil Shielded, Multiconductor

UL AWM 2501 VW-1

CSA AWM I/II A/B FT4

UL MTW

Operating Temperature

• –30°C to +105°C (AWM)

• –30°C to +90°C (MTW)

Conductor Color Coding

• Chart E (page 520)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Aluminum/polyester foil shield,

with 25% overlap and foil

facing inward

• Tinned copper drain wire sized

the same as cable conductors

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.032 (0.81 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5410/2

2

0.322

8.18

0.063

1.60

5410/3

3

0.337

8.56

0.063

1.60

5410/4

4

0.362

9.19

0.063

1.60

5410/5

5

0.389

9.88

0.063

1.60

5410/9

9

0.477

12.12

0.063

1.60

5410/12

12

0.525

13.34

0.063

1.60

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32 mm)

Insulation thickness: 0.032 (0.81 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5420/3

3

0.354

8.99

0.063

1.60

5420/4

4

0.381

9.68

0.063

1.60

5420/5

5

0.411

10.44

0.063

1.60

5420/7

7

0.442

11.23

0.063

1.60

5420/9

9

0.507

12.88

0.063

1.60

5420/12

12

0.558

14.17

0.063

1.60

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.032 (0.81 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5430/2

2

0.356

9.04

0.063

1.60

5430/3

3

0.373

9.47

0.063

1.60

5430/4

4

0.403

10.24

0.063

1.60

5430/5

5

0.436

11.07

0.063

1.60

5430/7

7

0.470

11.94

0.063

1.60

5430/9

9

0.539

13.69

0.063

1.60

5430/12

12

0.595

15.11

0.063

1.60

5430/15

15

0.647

16.43

0.063

1.60

5430/19

19

0.690

17.53

0.063

1.60

5430/25

25

0.800

20.32

0.063

1.60

Advertising