Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 13

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

41

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V

Xtra-Guard® 1

High Performance

300 V Foil Shielded, Multiconductor

UL CM

UL AWM 2343 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• Chart E (page 520)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Aluminum/polyester foil shield,

with 25% overlap and foil

facing inward

• Tinned copper drain wire sized

the same as cable conductors

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

24 AWG (0.23 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5599/3C

3

0.229

5.82

0.063

1.60

5599/5C

5

0.254

6.45

0.063

1.60

5599/7C

7

0.267

6.78

0.063

1.60

5599/12C

12

0.317

8.05

0.063

1.60

5599/15C

15

0.337

8.56

0.063

1.60

5599/19C

19

0.354

8.99

0.063

1.60

5599/27C

27

0.405

10.29

0.063

1.60

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5580/2C

2

0.234

5.94

0.063

1.60

5580C

5

0.270

6.86

0.063

1.60

5581C

7

0.285

7.24

0.063

1.60

5582C

12

0.342

8.69

0.063

1.60

5583C

15

0.365

9.27

0.063

1.60

5584C

19

0.384

9.75

0.063

1.60

5586C

37

0.484

12.29

0.063

1.60

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32

mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5560/2C

2

0.250

6.35

0.063

1.60

5560C

5

0.292

7.42

0.063

1.60

5561C

7

0.309

7.85

0.063

1.60

5562C

12

0.375

9.53

0.063

1.60

5563C

15

0.402

10.21

0.063

1.60

5564C

19

0.424

10.77

0.063

1.60

Advertising