Xtra-Guard® 5

Maximum Temperature and Chemical Performance

300 V Foil Shielded, Multiconductor

UL AWM 20229

UL CMP

CSA CMP FT6

Operating Temperature

• –80°C to +200°C

• –80°C to +150°C (AWM, CMP)

Conductor Color Coding

• Chart E (page 520)

• Nine jacket tints (tan standard)

• Custom colors available

Materials

• Stranded tinned copper

conductors

• FEP insulation

• FEP jacket

• Aluminum/polyester foil shield,

with 25% overlap and foil

facing inward

• Tinned copper drain wire sized

the same as cable conductors

• Aramid fiber ripcord

Availability

Made to order

1000 ft (305 m) minimum

FIT® Tubing Recommendations

• FIT-650: Chemical/temperature

resistant flexible fluoroelastomer

• FIT-400: Temperature/chemical

resistant FEP

18 AWG (0.90 mm

2

)

Stranding: 7/26 (7 x 0.40 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

55382

2

0.202

5.13

0.027

0.69

55383

3

0.213

5.41

0.027

0.69

55384

4

0.231

5.87

0.027

0.69

55386

6

0.271

6.88

0.027

0.69

55389

9

0.313

7.95

0.027

0.69

55390/12

12

0.349

8.86

0.027

0.69

16 AWG (1.23 mm

2

)

Stranding: 19/0.0117 (19 x 0.29 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

55362

2

0.224

5.69

0.027

0.69

55363

3

0.236

5.99

0.027

0.69

55364

4

0.257

6.53

0.027

0.69

55366

6

0.304

7.72

0.027

0.69

55369

9

0.353

8.97

0.027

0.69

55370/12

12

0.394

10.01

0.027

0.69

Advertising