Step 6: Adjust and Fasten Lock Side Mull Post.


Adjust lock side mull post so that the

weatherstrip contacts the door surface

equally at the top, middle, and bottom, an

even 3/8” – 1/2” when fully closed. Place a

screw through the pre-drilled hole in the

head jamb at the lock side mullion.

Do Not drive the screw completely in at this time.

Shim directly over lock side mull

post. Recheck lock mull post to

ensure weatherstrip contact is even

top to bottom. Finish driving screw

tight.



Step 7: Adjust and Secure Side Jambs.

Adjust the sidelite hinge jamb on the hinge

mull side of the unit to obtain even

weatherstrip contact top to bottom at the

lock side of the sidelite. Place a screw

through the hinge side jamb, into the stud, at

each remaining hinge location.

Do not drive the screws completely in at this

time.

Shim above the screws behind each hinge

location between the opening and the jamb

and make adjustment so the margin between

the sidelite and mullion are even top to

bottom. This margin will be slightly larger

than the margin at the door. Recheck

sidelite hinge jamb to ensure weatherstrip

contact is even top to bottom. Finish driving

screws tight.

Repeat the previous step on the sidelite hinge jamb on the lock mull side of

the unit.

Step 8: (French Door) Temporary Shim at Head Jamb.

When installing a French door

with active sidelites, place

temporary shims above the

center of the head frame,

where doors meet. Pre-drill

and insert a screw through

frame into header, then

remove the temporary shims.

Step 9: Remove Transport Clip and Open Door.

Remove transport clips. Confirm door and

sidelites operate properly.

Make adjustments as needed.

With sidelites open, drill 1/8” diameter pilot

holes and install the long hinge screws in the

hinge locations closest to the weatherstrip.

Do this for all hinges.

Step 10: Adjust Sill.

Your door unit has adjustable threshold caps. When properly adjusted, it

should be snug and slightly difficult to pull a dollar bill out from under the

door and sidelites when fully closed. The dollar bill should be able to be

removed without tearing.

This check should be performed at each

adjustment screw location on each active

threshold cap.



After adjusting the threshold cap, ensure that the

weatherstrip is flush with the top of the threshold

cap. Trim as necessary.


Step 11: Install Corner Seal Pads – Inswing units Only.

Apply sealant (Polyurethane or

Elastomeric) at the joint where the

threshold cap meets the jambs and

mull posts.

Remove the self-stick paper from

the corner seal pads and apply to the

jamb or mull post, with the bottom

lined up evenly with the top of the

threshold cap. When the pad is

correctly installed, the tab is on top

and the narrow part is on the

bottom.

The bottom of the pad is the same width of the threshold cap to help with

alignment during installation. Corner pads must be installed on both sides of

each active opening.