Adjusta-fit 2 prehanging instructions – Therma-Tru Doors Installation User Manual

Page 58

Advertising
background image

Installation

1.58

2014

SITE 1

Adjusta-Fit 2

Prehanging Instructions

DRIVE SECURITY SCREWS INTO

HINGE LEAVES.

CENTER UNIT IN OPENING AND

FASTEN FLANGES TO WALL.

For jambs exposed to weather: apply

sealant entire perimeter on underneath

side of nailing flange.

Place unit on correct side of opening.

Do not remove “L” bracket until door

is in place, plumb and shimmed.

Center unit in rough opening and set

flanges flush and plumb against wall.

Nail or screw flanges to wall through

punched holes at perimeter.

LOCATE AND SECURE SHIMS

BETWEEN WALL AND FRAME.

Hinge

jamb

shims,

located

behind

hinges.

Lock/

deadbolt

jamb

shims

DO NOT allow

shim force to twist

frame. Insufficient

shimming could

cause jamb to bow

at lock area allowing

door to come open

during a fire.

Keeping door closed, carefully shim between wall

and frame. Shim hinge jamb behind hinges and the

lock jamb as indicated in the figure below to plumb

and level the door. Remove “L” bracket from door.

With door open, at hinges where

indicated, drill 7/64” diameter pilot

holes and fasten #10 x 2 1/2” screws

(provided) through holes in each

hinge leaf.

(6) #10 x 2 1/2”

screws

FASTEN LOCK JAMB TO WALL

Close the door and finish securing the face of

the frame in the remaining holes.

7

6

4

5

1

CHECK ROUGH OPENING SIZE.

Check that door unit

is correct one for

opening.

Check rough opening

width and height for

the appropriate sill

type. See table below.

If additional carpet

clearance is required, the

necessary full shim under

the sill will change the

rough opening height

accordingly.

Rough Opening

Width

Rough Opening

Height

Floorline

2

CHECK ROUGH OPENING FOR

ACCURACY.

Is subfloor level?

Are walls plumb with jambs?

Are studs or door bucks plumb?

3

UNITS WITH PUBLIC ACCESS

SILLS, SEAL BOTTOM OF SILL

WARNING: It is critical for

proper fit and operation that

the rough opening is correct

For public access sills, apply sealant along

entire length of sill as shown.

Apply sealant here

Sill Type

Inswing

Public Access

No Sill

6/8

7/0

81 5/8” 85 5/8”

80 1/2”

85 1/2”

81”

85”

Sealant

(Contact your local Therma-Tru distributor

for alternate screw finishes.)

Undersize

TT Standard

6/8

7/0

81 1/4” 85 1/4”

80 1/8” 84 1/8”

80 5/8” 84 5/8”

Standard

Undersize

Rough Opening Height

Door Standard

2/0

25 1/16”

2/6

2/8

2/10

3/0

3/6

3

1 1/16

33

1/16

35

1/16

37

1/16

43

1/16

2/4

29

1/16

Undersize

25”

31”

33”

35”

37”

43”

29”

Rough Opening Width

Advertising