SITE 1

Adjusta-Fit 2

Prehanging Instructions

CODES

Building codes may vary from area to area.

If a fire rating is required of the door and

opening being framed, the installer must

use installation materials and methods to

satisfy the authority having jurisdiction.

Therma-Tru provides labeled products,

but bears no responsibility for installation.

Read instructions carefully before

installing your new Therma-Tru

Adjusta-Fit

®

2 system.

all

Please note there are separate “Prehanging

Instructions” to be reviewed and followed

prior to completing the installation.

Site

Installation

Instructions

for

Adjusta-Fit

®

2

1750 Indian Wood Circle Maumee, Ohio 43537

1-800-THERMA-TRU (843-7628)

www.thermatru.com

Therma-Tru Positive Pressure

(NFPA-252/UL-10C/CAN4-S104)

Labeled Systems

© Copyright 2009 Therma-Tru Corp. All rights reserved. Therma-Tru Corp. is an

operating company of Fortune Brands, Inc. All trademarks are property of their

respective owners. 3/2009 Part # MSLCMFIST

This Therma-Tru door system has been labeled in

compliance with NFPA-252/UL-10C/CAN4-S104

Positive Pressure Smoke and Draft control rating and

requires a listed Category “H” gasket and the

application of an additional Category

edge

sealing system. To maintain the validity of this

certification, the door installer must follow these

instructions. They should be kept on file on the

building premises for verification by the authority

having jurisdiction.

Verify that the frame is compatible with the

door and properly installed.

Install hardware per the hardware

manufacturer's instructions.

For Positive Pressure Rating, a listed and

labeled category “G” edge seal shall be

installed into the opening.

For smoke rating, a listed and labeled

category “H” Smoke and Draft control

gasket (included) shall be installed into the

opening.

Installation must comply with requirements

of NFPA 80 “Standard for Fire Doors and

Fire Windows”.

Surface mounted hardware must be attached

with through bolts unless interior

“G”