Installation

1.40

2014

SITE 1

Multi-Point Shootbolt

Coastal Astragal 2 Installation Instructions

2

DRILL HEAD AND SILL BOLT HOLES.

Rev. 12/20/02

4

Position keeper plates as shown at

overhead and sill holes.

Fasten plates with (2) #8 x 2-1/2” screws.

INSTALL KEEPER PLATES.

Astragal Keeper Plates

with

#8 x 2-1/2” screws

3

INSERT ASTRAGAL FILL PLUG INTO

THRESHOLD.

Apply additional sealant to underside of lip of

sill plug.

Fit should be tight, sealant will act as adhesive.

Open door and drill 3/8” diameter hole at overhead

in wood frame 2” deep.

Drill 1/2” diameter hole through threshold 2-1/4”

deep. If sub-floor material is masonry, a 1/2” diameter

masonry drill bit will be needed to complete hole.

Apply significatnt amount of sealant to threshold

hole to seal sub-floor interface area.

Deep Sill Plug