Rockwell Automation 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx User Manual

Page 6

Advertising
background image

English-4

Refer to the PowerFlex 40 User Manual for details on how to comply

with the Low Voltage (LV) and Electromagnetic Compatibility (EMC)

Directives.

CE Conformity

Specifications, Fuses and Circuit Breakers

Drive Ratings

Catalog

Number

(1)

Output Ratings

Input Ratings

Branch Circuit Protection

Power

Dissipation

kW (HP)

Amps

Voltage

Range

kVA Amps Fuses

140M Motor

Protectors

Contactors

IP20 Open

Watts

100 - 120V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output

22B-V2P3x104 0.4 (0.5)

2.3

90-132

1.15 9.0

15

140M-C2E-C16 100-C12

40

22B-V5P0x104 0.75 (1.0)

5.0

90-132

2.45 20.3

35

140M-D8E-C20 100-C23

60

22B-V6P0x104 1.1 (1.5)

6.0

90-132

3.0

24.0

40

140M-F8E-C32 100-C37

80

200 - 240V AC (±10%) – 1-Phase

(2)

Input, 0 - 230V 3-Phase Output

22B-A2P3x104 0.4 (0.5)

2.3

180-264

1.15 6.0

10

140M-C2E-B63 100-C09

40

22B-A5P0x104 0.75 (1.0)

5.0

180-264

2.45 12.0

20

140M-C2E-C16 100-C12

60

22B-A8P0x104 1.5 (2.0)

8.0

180-264

4.0

18.0

30

140M-D8E-C20 100-C23

85

22B-A012x104

2.2 (3.0)

12.0

180-264

5.5

25.0

40

140M-F8E-C32 100-C37

125

200 - 240V AC (±10%) – 3-Phase Input, 0 - 230V 3-Phase Output

22B-B2P3x104 0.4 (0.5)

2.3

180-264

1.15 2.5

6

140M-C2E-B40 100-C07

40

22B-B5P0x104 0.75 (1.0)

5.0

180-264

2.45 5.7

10

140M-C2E-C10 100-C09

60

22B-B8P0x104 1.5 (2.0)

8.0

180-264

4.0

9.5

15

140M-C2E-C16 100-C12

85

22B-B012x104

2.2 (3.0)

12.0

180-264

5.5

15.5

25

140M-C2E-C16 100-C23

125

22B-B017x104

3.7 (5.0)

17.5

180-264

8.6

21.0

30

140M-F8E-C25 100-C23

180

22B-B024x104

5.5 (7.5)

24.0

180-264

11.8 26.1

40

140M-F8E-C32 100-C37

235

22B-B033x104

7.5 (10.0)

33.0

180-264

16.3 34.6

60

140M-G8E-C45 100-C60

305

380 - 480V AC (±10%) – 3-Phase

Input, 0 - 460V 3-Phase Output

22B-D1P4x104 0.4 (0.5)

1.4

342-528

1.4

1.8

3

140M-C2E-B25 100-C07

35

22B-D2P3x104 0.75 (1.0)

2.3

342-528

2.3

3.2

6

140M-C2E-B40 100-C07

50

22B-D4P0x104 1.5 (2.0)

4.0

342-528

4.0

5.7

10

140M-C2E-B63 100-C09

70

22B-D6P0x104 2.2 (3.0)

6.0

342-528

5.9

7.5

15

140M-C2E-C10 100-C09

100

22B-D010x104

4.0 (5.0)

10.5

342-528

10.3 13.0

20

140M-C2E-C16 100-C23

160

22B-D012x104

5.5 (7.5)

12.0

342-528

11.8 14.2

25

140M-D8E-C20 100-C23

175

22B-D017x104

7.5 (10.0)

17.0

342-528

16.8 18.4

30

140M-D8E-C20 100-C23

210

22B-D024x104

11.0 (15.0) 24.0

342-528

23.4 26.0

50

140M-F8E-C32 100-C43

300

460 - 600V AC (±10%) – 3-Phase

Input, 0 - 575V 3-Phase Output

22B-E1P7x104 0.75 (1.0)

1.7

414-660

2.1

2.3

6

140M-C2E-B25 100-C09

50

22B-E3P0x104 1.5 (2.0)

3.0

414-660

3.65 3.8

6

140M-C2E-B40 100-C09

70

22B-E4P2x104 2.2 (3.0)

4.2

414-660

5.2

5.3

10

140M-C2E-B63 100-C09

100

22B-E6P6x104 4.0 (5.0)

6.6

414-660

8.1

8.3

15

140M-C2E-C10 100-C09

160

22B-E9P9x104 5.5 (7.5)

9.9

414-660

12.1 11.2

20

140M-C2E-C16 100-C16

175

22B-E012x104

7.5 (10.0)

12.2

414-660

14.9 13.7

25

140M-C2E-C16 100-C23

210

22B-E019x104

11.0 (15.0) 19.0

414-660

23.1 24.1

40

140M-D8E-C25 100-C30

300

(1)

In the Catalog Numbers listed “x” represents enclosure type. Specifications are valid for all

enclosure types. IP66, NEMA/UL Type 4X drive ratings are only available as Frame B drives.

(2)

200-240V AC - 1-Phase drives are also available with an integral EMC filter. Catalog suffix

changes from N104 to N114. Filter option is not available for IP66, NEMA/UL Type 4X rated drives.

Advertising