Heatsink surface and flatness requirements, Plate drive installation instructions h-3 – Rockwell Automation 22D PowerFlex 40P User Manual, FRN 3 User Manual
Page 193

Plate Drive Installation Instructions
H-3
Heatsink Surface and Flatness Requirements
The drive comes with a thermal pad designed to provide a good interface
between the drive and heatsink. However, in order for this to function
properly the mounting surface for the plate drive must be clean and free
of dirt, oil, and debris. It must be very flat and smooth and should have
no scratches, nicks, or gouges. All mounting holes must be clean and
deburred.
Table H.C Surface Requirements
Figure H.2 Smoothness Tolerance and Surface Pad Thickness
Figure H.3 Trueness Tolerance
Attribute
Requirement
Description
Surface Finish
1.6 µM (Ra Method)
Smoothness – Overall surface texture free from
imperfections (scratches, nicks, or gouges)
Surface Flatness
-/+ 1.5 mil
Trueness – Free from warps, twists, and concavity
(depressions)
5.0 mil
+0.5 mil
–0.5 mil
+1.5 mil
–1.5 mil