Installation/Wiring

1-31

Main Control Board I/O and
Encoder Settings

Table 1.K Switch Settings

Please note there are two separate values for an encoder.

S1

1 2

FRONT

TOP VIEW

SIDE VIEW

Up = Open = Off

Down = Closed = On

SWITCH S5

FRONT

TOP VIEW

SIDE VIEW

Up = Open = Off

Down = Closed = On

SWITCH S2

1 2

3 4

1 2

FRONT

TOP VIEW

SIDE VIEW

Up = Open = Off

Down = Closed = On

SWITCH S3

1 2

FRONT

TOP VIEW

SIDE VIEW

Up = Open = Off

Down = Closed = On

SWITCH S4

= HW Enable

= No HW Enable

JUMPER P22

1

2

3

4

1

2

3

4

Function

Switch

Open

Closed

Default

Notes

Configuring Digital Input 6 for
Hardware Enable (HW Enbl)

P22
Jumper

pin 2-4
HW enable

pin 1-3
No enable

pin 2-4
HW enable

No jumper = HW enable

Analog Input 1

S5-1

Voltage

Current

Voltage

Change with Power Off.

Analog Input 2

S5-2

Voltage

Current

Voltage

Change with Power Off.

Digital Inputs 4-6 Voltage

S4-1, S4-2

115V ac

24V dc

24V dc

Change with Power Off.

Digital Input 1 Voltage

S3-1

24V dc

12V dc

24V dc

Change with Power Off.

Digital Input 2 Voltage

S3-2

24V dc

12V dc

24V dc

Change with Power Off.

Encoder Voltage Supply

S2-1

12V dc

5V dc

24V dc

Change with Power Off.

Set all switches the same.

Encoder Signal A Voltage

S2-2

12V dc

5V dc

12V dc

Encoder Signal B Voltage

S2-3

12V dc

5V dc

12V dc

Encoder Signal Z Voltage

S2-4

12V dc

5V dc

12V dc

Function

Switch

Open

Closed

Default

Notes