Troubleshooting

Drive Status

Power Module LED Indications

The Inverter Status LED and Rectifier Status LED are located on the DPI
Communications Interface Board on the front of the power module. The
LEDs indicate the status of the inverter and the rectifier as shown in the
table in

Figure 3.1

. Note that if the LEDs are off, it indicates the drive is not

receiving power.

Figure 3.1 Inverter and Rectifier Status LEDs and Indications

DPI Communications
Interface Board
(front surface of
power module)

Inverter Status LED

Rectifier Status LED

Color

State

Description

Green

Flashing

Drive ready, but not running and no faults are present.

Steady

Drive running, no faults are present.

Yellow

Flashing

A type 2 (non-configurable) alarm condition exists, but drive continues to run.

Steady

A type 1 (user configurable) alarm condition exists, but drive continues to run.

Red

Flashing

A fault has occurred.

Steady

A non-resettable fault has occurred.