Wiring diagrams c-9, 80w power supply, Inverter power interface assy – Rockwell Automation LPM20 Liquid-Cooled AC Drive with High Performance Drive Control User Manual

Page 83

Advertising
background image

Wiring Diagrams

C-9

UPPER GATE

U

POWER

V

OUTPUT

W

NC

J11

1

3

4

2

GATE KILL

BLOCK

TERMINAL

EXTERNAL-

SWITCH

9

5

7
6

8

A33

24V_COM

COIL_RETURN

+24V

+24V

DC BUS

FEEDBACK

IN

CURRENT

INTERFACE

LOGIC SUPPLY

I/F IN

2

1

+24V

OVER_TEMP_2

OVER_TEMP_1

GATE KILL

INTERNAL I/O

SUPPLY I/F

IN

LOWER GATE

DISTRIBUTION

DC BUS

IN

SUPPLY I/F

To DC BUS
See Pages
C-10/C-11

INVERTER +DC BUS

3

2

4

LOGIC SUPPLY

10

+24V

10

INVERTER -DC BUS

1

J1

11

+24V

11

-12V

+12V
24V_COM

AD_COM

8
9

7

6

AD_COM
AD_COM

2

5

4

3

5V

5V

9

8

7

6

OUT

5

4

3

2

JP1

SUPPLY OUT

LOWER GATE

2

7

BUS_FB

J4

1

8

J2

1

J1

1

P_VLO+
P_VLO-
P_WLO+
P_WLO-

3
4
5
6

P_ULO-

P_ULO+

J3

2

1

6

3

4

5

8
7

DC BUS INTERFACE

80W POWER SUPPLY

193087-A02

A24

2

MAIN

See Table on Page C-11

TEMPERATURE

SENSE IN

IGBT

INTERFACE

GATE

DRIVER

GATE

INVERTER POWER

INTERFACE ASSY.

A23

INTERFACE

DRIVER

INTERFACE

CONTROL

DRIVER

INTERFACE

GATE

J13

TO INVERTER IGBT ASSY. #1-J1

TO INVERTER IGBT ASSY. #2-J1

UPPER GATE SUPPLY OUPUT/

INVERTER NTC1+
INVERTER NTC1-

INVERTER NTC2+
INVERTER NTC2-

3
4

1
2

TO INVERTER IGBT ASSY. #2-J1

TO INVERTER IGBT ASSY. #2-J3

INVERTER W-COLLECTOR

8

INVERTER W-GATE
INVERTER W-EMITTER

12
13

11

10

9

INVERTER V-COLLECTOR

INVERTER V-GATE
INVERTER V-EMITTER

5

4

7

6

1

3

2

TO INVERTER IGBT ASSY. #1-J2

TO INVERTER IGBT ASSY. #2-J1

10

INVERTER U-GATE
INVERTER U-EMITTER

14

J8

11
12
13

INVERTER W+GATE
INVERTER W+EMITTER

INVERTER U-COLLECTOR

6
7

9

8

3

2

5

4

TO INVERTER IGBT ASSY. #2-J3

TO INVERTER IGBT ASSY. #1-J2

INVERTER W+COLLECTOR

INVERTER V+GATE
INVERTER V+EMITTER

J7

1

11
12

INVERTER U+EMITTER

INVERTER U+GATE

INVERTER V+COLLECTOR

8
9

10

7

5

4

6

3

INVERTER U+COLLECTOR

J6

1

CURRENT FEEDBACK PWR-

CURRENT FEEDBACK PWR+

CURRENT FEEDBACK SIGU
CURRENT FEEDBACK PWR+
CURRENT FEEDBACK PWR-
CURRENT FEEDBACK SIGV
CURRENT FEEDBACK PWR+
CURRENT FEEDBACK PWR-
CURRENT FEEDBACK SIGW

13

7

4

+DC

J3

J2

5

-DC

1
2
3

J14

1

4

2

3

3
2
1

P_WUP-
P_WUP+

6

4

5

P_VUP-
P_VUP+

9
8

6

7

12

10

11

10

8

9

P_UUP-
P_UUP+

16

14

15

FACTORY-INSTALLED JUMPERS

OPTION

AC

J9

4

7
8

5

6

1

3

2

23

33

38
39
40

35
36

34

37

28

30
31

29

32

26
27

25

24

13

18
19

21
22

20

15

14

17

16

8
9
10

12

11

6

5

4

7

J5

1
2
3

To DC BUS
See Pages
C-10/C-11

V_ISO-

V_ISO+

See
Pages
C-10/C-11

Advertising